Elite RS 1 Loop, Grey Color Analogue Addressable Fire Control Panel UL/FM Approved Elite RS is a versatile range of open protocol fire alarm control panels. Available with one or two detection loops capable of hosting up to 254 Hochiki or Apollo UL devices. Elite RS uses microprocessor-based electronics to provide a flexible control system with high reliability and integrity.…
Elite RS 2 Loop, Red Color Analogue Addressable Fire Control Panel UL/FM Approved Elite RS is a versatile range of open protocol fire alarm control panels. Available with one or two detection loops capable of hosting up to 254 Hochiki or Apollo UL devices. Elite RS uses microprocessor-based electronics to provide a flexible control system with high reliability and integrity.…
Elite RS 2 Loop, Grey Color Analogue Addressable Fire Control Panel UL/FM Approved Elite RS is a versatile range of open protocol fire alarm control panels. Available with one or two detection loops capable of hosting up to 254 Hochiki or Apollo UL devices. Elite RS uses microprocessor-based electronics to provide a flexible control system with high reliability and integrity.…
Sigma A-XT Surface mounting panel - Red 230V Sigma A-XT releasing panel offers outstanding value and performance for all small to medium fixed firefighting installations. With three initiation circuits as standard, release can be configured to activate from any combination of detection zone inputs to allow (among other combinations) any two from three types of activations. For example, as would…
Multi-Criteria Sensor ACC-V, a Multi-Criteria Sensor that is particularly suited for detecting smoke produced by a wide range of combustibles found in various applications. Temperature monitoring is achieved by a thermistor placed for optimum sensitivity. UL Approved Fire Detection Product code: ACC-V
Hochiki Analog Photo Smoke Sensor ALN-V, a Photoelectric Smoke Sensor that's particularly suited to detecting optically dense smoke typical of fires involving materials such as soft furnishings, plastic, foam, or other similar materials that tend to smolder and produce large visible smoke particles. Hochiki's unique design allows fast response to flaming fires as well as smoldering fires while preventing false…
Hochiki Analog Heat Sensor ATJ-EA, a Fixed Temperature / Rate of Rise sensor that provides accurate temperature measurement data to the fire alarm control panel. These sensors are well-suited for environments where dust, cooking fumes, or other factors make the use of smoke sensors impractical. Low profile - only 2.00" high, including base Approved UL Fire Detection Product code :…
Single Action with Key Lock Addressable Manual Pull Station DCP-AMS are the Hochiki America series of addressable manual pull stations that provide a fast and practical means of manually initiating a fire alarm signal. Both single-action and dual-action manual pull stations are available. Resetting of the pull station requires either a Cat 30 key or a 1/8" hex key (depending…
Dual Action Addressable Manual Pull Station DCP-AMS are the Hochiki America series of addressable manual pull stations that provide a fast and practical means of manually initiating a fire alarm signal. Both single-action and dual-action manual pull stations are available. Resetting of the pull station requires either a Cat 30 key or a 1/8" hex key (depending upon the model…
4" SENSOR BASE, BONE COLOR The YBN-NSA-4 and HSB-NSA-6 are designed specifically for use with the Hochiki NS Analog models AIEEA, ALG-V, ALK-V, ALK-D, ALN-V, ATG-EA, ATJ-EA and ACA-V. The YBN-NSA-4 and HSB-NSA-6 common mounting bases allows for complete compatibility for all of the Hochiki NS Series Analog sensors. The bases are lightweight and very thin, providing a low profile…
6" SENSOR BASE, BONE COLOR The YBN-NSA-4 and HSB-NSA-6 are designed specifically for use with the Hochiki NS Analog models AIEEA, ALG-V, ALK-V, ALK-D, ALN-V, ATG-EA, ATJ-EA and ACA-V. The YBN-NSA-4 and HSB-NSA-6 common mounting bases allows for complete compatibility for all of the Hochiki NS Series Analog sensors. The bases are lightweight and very thin, providing a low profile…
SCI-B4 - 4" SENSOR BASE, BONE COLOR WITH ISOLATOR The HOCHIKI America SCI-B4 and the SCI-B6 are short circuit isolation mounting bases containing a simple rugged design with screw terminals for wiring connections. These common mounting bases allows sensor interchange and maintains loop continuity when sensors are removed. A simple anti-tamper head locking system is provided which is enabled by…
SCI-B6 - 6" SENSOR BASE, BONE COLOR WITH ISOLATOR The HOCHIKI America SCI-B4 and the SCI-B6 are short circuit isolation mounting bases containing a simple rugged design with screw terminals for wiring connections. These common mounting bases allows sensor interchange and maintains loop continuity when sensors are removed. A simple anti-tamper head locking system is provided which is enabled by…
CLIM-1 CURRENT LOOP INPUT MODULE, SINGLE INPUT The Current Loop Input Module (CLIM) is ideal for sensors and devices in environments such as HVAC, Boiler Equipment, Oil & Gas, and Explosive areas that provide a 4-20 mA output Product code: CLIM-1 CURRENT LOOP INPUT MODULE, SINGLE INPUT CLIM-2 CURRENT LOOP INPUT MODULE, DUAL INPUT
CLIM-2 CURRENT LOOP INPUT MODULE, DUAL INPUT The Current Loop Input Module (CLIM) is ideal for sensors and devices in environments such as HVAC, Boiler Equipment, Oil & Gas, and Explosive areas that provide a 4-20 mA output Product code: CLIM-1 CURRENT LOOP INPUT MODULE, SINGLE INPUT CLIM-2 CURRENT LOOP INPUT MODULE, DUAL INPUT
Conventional Zone Input Module DCP-CZM, the Conventional Zone Module is designed for use on an analog addressable Fire Alarm system. Up to 127 devices can be placed on a single SLC loop. The device address is uniquely stored on an onboard EEPROM The module allows the panel to interface and monitor two-wire conventional detectors or pull stations. Each DCP-CZM transmits…
DH-100-A ADDRESSABLE DUCT DETECTOR The HOCHIKI AMERICA DH-100-A Analog duct smoke detector provides early detection of smoke and products of combustion present in air moving through HVAC ducts in Commercial, Industrial and Residential applications. The DH-100-A is designed to prevent the recirculation of smoke in areas by the air handling systems, fans and blowers. Complete systems may be shut down…
DH-99 DIGITAL ANALOG DUCT DETECTOR The HOCHIKI AMERICA DH-99 Digital Analog duct smoke detector provides early detection of smoke and products of combustion present in air moving through HVAC ducts in Commercial, Industrial and Residential applications. The DH-99 is designed to prevent the recirculation of smoke in areas by the air handling systems, fans and blowers. Complete systems may be…
DH-99 DIGITAL ANALOG DUCT DETECTOR The HOCHIKI AMERICA DH-99 Digital Analog duct smoke detector provides early detection of smoke and products of combustion present in air moving through HVAC ducts in Commercial, Industrial and Residential applications. The DH-99 is designed to prevent the recirculation of smoke in areas by the air handling systems, fans and blowers. Complete systems may be…
Dual Input Monitor Module DCP-DIMM (Dual Input Monitor Module) is designed for use on a UL-listed Fire Alarm Control Panel. It provides two independent contact monitoring circuits while only utilizing one address on the SLC loop. Up to 127 devices can be placed on a single SLC loop. The device address is uniquely stored on an onboard EEPROM. The module…
Fast Response Contact Monitor for 4" Box Class A Isolator The Hochiki FRCMA/-I Fast Response Contact Monitoring Modules are designed to be used with pull stations, water flow switches, and other applications requiring the monitoring of dry contact alarm initiating devices.The interrupt driven Digital Communications Protocol (DCP)combines maximum communication reliability and fast response to emergency conditions.
Fast Response Contact Monitoring Module The Hochiki DCP-FRCME-M Fast Response Contact Monitoring Modules are designed to be used with pull stations, water flow switches, and other applications requiring the monitoring of dry contact devices. The interrupt driven Digital Communications Protocol (DCP) combines maximum communication reliability and fast esponse to emergency conditions. The DCP-FRCMEM contact monitoring module does not require a…
FAST RESPONSE CONTACT MONITORING MODULE WITH PIGTAILS The Hochiki DCP-FRCME-M Fast Response Contact Monitoring Modules are designed to be used with pull stations, water flow switches, and other applications requiring the monitoring of dry contact devices. The interrupt driven Digital Communications Protocol (DCP) combines maximum communication reliability and fast response to emergency conditions. The DCP-FRCMEM contact monitoring module does not…
Dual Relay Module 24v or 220V, 8 AMPS The Dual Relay Modules (R2ML/H Series) have been designed to provide flexible and quick response to emergency conditions. The R2ML/H Series allows independent control of two form C contacts for a variety of normally open and normally closed contact applications such as fan operation, elevator recall, door closure, ad auxiliary notification. Product code:…